Capacity:10kg 40kg 80kg
Dimension: 88×23x21mm
QTY:200pcs/ctn
TECHNICAL SPECIFICATION
Rated output | mV/V | 2.0±0.1 |
Accuracy class | C3 | |
Maximum number of verification intervals | n... | 3000 |
Minimum load cell verification intervals | V... | Emax/7500 |
Combined erro | %RO | ≤±0.020 |
Creep | %RO/30min | 0.017 |
Temperature effect on sensitivity | %RO/℃ | 0.0017 |
Temperature effect on zero | %RO/℃ | 0.002 |
Zero balance | %RO | ±1.5 |
lnput resistance | Ω | 401±5 |
Output resistance | Ω | 350±3 |
lnsulation resistance | MΩ | 5000 |
Recommended excitation voltage | V | 10~15 |
Compensated temperature range | ℃ | -10~+40 |
Operating temperature range | ℃ | 20~+70 |
Safe overload | %RO | 150 |
ultimate overload | %RO | 200 |
load cell material | Aluminium | |
Method of connecting wire | Red E+ Black E- White S+ Green S- |